• support@dumpspool.com

SPECIAL LIMITED TIME DISCOUNT OFFER. USE DISCOUNT CODE TO GET 20% OFF DP2021

PDF Only

$35.00 Free Updates Upto 90 Days

  • H19-371_V1.0 Dumps PDF
  • 653 Questions
  • Updated On July 26, 2024

PDF + Test Engine

$60.00 Free Updates Upto 90 Days

  • H19-371_V1.0 Question Answers
  • 653 Questions
  • Updated On July 26, 2024

Test Engine

$50.00 Free Updates Upto 90 Days

  • H19-371_V1.0 Practice Questions
  • 653 Questions
  • Updated On July 26, 2024
Check Our Free Huawei H19-371_V1.0 Online Test Engine Demo.

How to pass Huawei H19-371_V1.0 exam with the help of dumps?

DumpsPool provides you the finest quality resources you’ve been looking for to no avail. So, it's due time you stop stressing and get ready for the exam. Our Online Test Engine provides you with the guidance you need to pass the certification exam. We guarantee top-grade results because we know we’ve covered each topic in a precise and understandable manner. Our expert team prepared the latest Huawei H19-371_V1.0 Dumps to satisfy your need for training. Plus, they are in two different formats: Dumps PDF and Online Test Engine.

How Do I Know Huawei H19-371_V1.0 Dumps are Worth it?

Did we mention our latest H19-371_V1.0 Dumps PDF is also available as Online Test Engine? And that’s just the point where things start to take root. Of all the amazing features you are offered here at DumpsPool, the money-back guarantee has to be the best one. Now that you know you don’t have to worry about the payments. Let us explore all other reasons you would want to buy from us. Other than affordable Real Exam Dumps, you are offered three-month free updates.

You can easily scroll through our large catalog of certification exams. And, pick any exam to start your training. That’s right, DumpsPool isn’t limited to just Huawei Exams. We trust our customers need the support of an authentic and reliable resource. So, we made sure there is never any outdated content in our study resources. Our expert team makes sure everything is up to the mark by keeping an eye on every single update. Our main concern and focus are that you understand the real exam format. So, you can pass the exam in an easier way!

IT Students Are Using our HCS-Pre-sales-Digital Power V1.0 Dumps Worldwide!

It is a well-established fact that certification exams can’t be conquered without some help from experts. The point of using HCS-Pre-sales-Digital Power V1.0 Practice Question Answers is exactly that. You are constantly surrounded by IT experts who’ve been through you are about to and know better. The 24/7 customer service of DumpsPool ensures you are in touch with these experts whenever needed. Our 100% success rate and validity around the world, make us the most trusted resource candidates use. The updated Dumps PDF helps you pass the exam on the first attempt. And, with the money-back guarantee, you feel safe buying from us. You can claim your return on not passing the exam.

How to Get H19-371_V1.0 Real Exam Dumps?

Getting access to the real exam dumps is as easy as pressing a button, literally! There are various resources available online, but the majority of them sell scams or copied content. So, if you are going to attempt the H19-371_V1.0 exam, you need to be sure you are buying the right kind of Dumps. All the Dumps PDF available on DumpsPool are as unique and the latest as they can be. Plus, our Practice Question Answers are tested and approved by professionals. Making it the top authentic resource available on the internet. Our expert has made sure the Online Test Engine is free from outdated & fake content, repeated questions, and false plus indefinite information, etc. We make every penny count, and you leave our platform fully satisfied!

Frequently Asked Questions

Huawei H19-371_V1.0 Sample Question Answers

Question # 1

For an IT load of 80kW, a UPS system of 80kVA can meet the basic needs.

 A. True 
B. False 

Question # 2

In air-cooled precision air conditioners, the role of solenoid valves is to prevent refrigerant migration, optimize control, and protect compressors 

A. True 
B. False 

Question # 3

The PDU8000 precision power distribution cabinet adopts a 7-inch liquid color touch screen, which can graphically display the system diagram of the power distribution cabinet and the status of each switch. 

A. True 
B. False 

Question # 4

The system efficiency of the UPS5000-E-75K half-height cabinet modular UPS is also 96% ( ) 

A. True 
B. False 

Question # 5

Fusion800 has the function of self-starting of civil air conditioner

 A. True
 B. False 

Question # 6

The smoke sensor used in the NetEco6000 management system cannot replace the smoke sensor in the fire protection system. ( ).

 A. True 
B. False

Question # 7

FusionModule800 can only support lower pipe () 

A. True 
B. False 

Question # 8

Configure the cables of the UPS. The total current-carrying capacity of the cables is greater than the rated current of the UPS to meet the requirements of the project. () /

A. True 
B. False 

Question # 9

Huawei precision air conditioners have power over-voltage, under-voltage alarm and fault diagnosis alarm record functions, automatic protection, automatic recovery, automatic restart and other functions. 

A. True 
B. False 

Question # 10

To configure the UPS cable, it is necessary to consider the rated current of the UPS and the voltage drop on the line for selection 

A. True 
B. False 

Question # 11

FusionModule1000A V2R3 version 40-foot IT solution can provide 7~8 IT cabinets

 A. True
 B. False 

Question # 12

The UPS5000-S power module has a capacity of 50kVA and a height of 2U, the highest power density in the industry. 

A. True
B. False 

Question # 13

Which of the following are the working modes of UPS2000-A-(1K-10K)? () (multiple choice) 

A. Mains mode 
B. Battery Mode 
C. Static Bypass Mode 
D. Manual maintenance bypass mode 

Question # 14

Load 120kW, use UPS5000-S to meet N+2 modular redundancy configuration, can be configured ( ) kVA models+ 

A. 160kVA 
B. 200kVA 
C. 240kVA 
D. 250kVA 

Question # 15

Which of the following statements about iBattery is true? (Multiple choice)

A. In the scenario of micro module A, the CIM is connected to the ETH socket 
B. In the scenario of Micro Module B, the CIM is connected to the UPS 
C. CIM can be powered by PoE and 48V power supply 
D. CIM northbound signal is transmitted wirelessly 
E. The BIM signal is wirelessly connected to the CIM 

Question # 16

Which of the following are the main features of the UPS2000-G-(6K-20K) PDU? 

A. Realize the input and output power distribution of two parallel machines 
B. Provide single or parallel system centralized maintenance bypass 
C. Extended output socket: OT: 4*C13; 2*C19 
D. Provide surrounding environment monitoring and alarm 

Question # 17

What are the functions of Al-Robot?. 

A. Intelligent recognition 
B. Temperature cloud map 
C. Accompanying visitors 
D. Remote inspection 
E. Automatic inspection 

Question # 18

Which of the following statements about wet film humidification is correct? ( ).

 A. No need to heat 
B. Increased wind resistance. 
C. 95%+ energy saving than electrode humidification, better life cycle TCO 
D. Compared with electrode humidification, it has lower water quality requirements and no additional water treatment equipment. 

Question # 19

When selecting UPS cables, the problems to be considered are () 

A. UPS-related current rating
 B. The rated working voltage and rated insulation voltage of the cable 
C. Voltage drop across the cable path 
D. Number of parallel cables 

Question # 20

Assuming that a certain battery specification stipulates that the discharge power is 400W@ 1.67V @15min, if the system demand is 1400W, the number of battery packs A. selected is: ()/ 

A. Group 5 
B. Group 3 
C. Group 4 

Question # 21

What type of UPS does UPS5000-E (50kVA power module) belong to? ( ) 

A. Power frequency machine 
B. High frequency machine 
C. Rack Tower Compatible D. Modular Answer: B,D
D. Modular 

Question # 22

When multiple FusionModule products are used in the same project, when configuring NetEco, the associated application scenario should be selected () 

A. Customize 
B. FusionModule2000 
C. Associate the FusionMoudle family 
D. FusionMoudle5000

Question # 23

The NetEcoo6000 management system can provide monitoring of the cooling power system, and which of the following functions can it provide? (Multiple choice) 

A. The power distribution system topology diagram can be provided, and the power distribution system diagram of the entire computer room can be displayed 
B. Support the display of key equipment indicators on the power distribution topology diagram, which is convenient for users to understand the operation status of the system and important nodes 
C. It can provide the topological diagram of the chilled water system, showing the operation status of the whole system 
D. None of the above is supported 

Question # 24

What kind of access control can the rear door of the FusionModule2000 cabinet support? A Mechanical code lock B IC card swipe access control C Three-in-one access control D None of the above Answers: D 216. The NetEco6000 management system can provide energy efficiency management functions. Which of the following functions are supported? (multiple choice)

A. The PUE of the computer room can be monitored to understand the current energy efficiency level 
B. You can understand the energy expenditure cost of the computer room according to the electricity cost of the computer room with the stepped electricity price 
C. The pPUE of each micro-module can be monitored to understand the energy efficiency level of each micro-module 
D. The electricity consumption report of each cabinet can be generated, which is convenient for customers to count the electricity consumption of each department. 

Question # 25

UPS5000-E (25- 75kVA) integrated cabinet includes () ? (multiple choice) 

A. Input switch 
B. Output switch 
C. Battery switch 
D. Maintenance Bypass Switch 

Question # 26

Which of the following alarm functions does the main circuit of the PDU800 power distribution cabinet have? () 

A. Current high reading value out-of-limit alarm 
B. Overvoltage alarm 
C. The main circuit is powered off 
D. Abnormal frequency 
E. Undervoltage alarm 

Question # 27

The NetEco6000 management system can provide the temperature cloud map function to realize the identification of cold and hot spots in the computer room. How many layers of temperature maps does the temperature cloud map support? ( ). 

A. Single layer 
B. Double layer
 C. Three floors 
D. Fourth floor 

Question # 28

When the single cell voltage in the battery pack reaches ( ), it means that the battery pack is already in a state of risk. / 

A. 2.42V 
B. 2.25V 
C. 2.35V 
D. 1.67V 

Question # 29

What kind of cable entry and exit methods can FusionModule2000 precision power distribution cabinet realize? ( ) 

A. Top in and online out 
B. Top-in line and bottom-out line 
C. Down in and out on the line 
D. Down in and out of the line 

Question # 30

The DC cable voltage drop needs to be controlled within ( ). () 

A. 0.03 
B. 0.01 
C. 0.02 
D. 0.05 

Question # 31

Which of the following functions or components does the UPS6000-E (50kVA power module) come standard with? ( ) 

A. Dry contact communication card 
B. Parallel function 
C. SNMP function 
D. Bus synchronization control function

Question # 32

What functions does the iCooling feature of FusionModule2000 V3.0 include? ( ) 

A. AI self-optimization algorithm, air conditioner saves 8% of energy 
B. Temperature cloud map and air conditioning linkage 
C. Refrigerant capacity alarm function 
D. Refrigeration system visibility 

Question # 33

Regarding the selection of the outdoor unit of NetCol5000, what conditions should be considered ( ). 

A. Altitude. 
B. Distance from the sea 
C. Outdoor sandstorm conditions. 
D. Indoor unit cooling capacity 

Question # 34

In a project that requires the deployment of three-layer temperature cloud maps in highdensity areas, it is necessary to deploy () temperature probes in each cabine

A. 2 
B. 6 
C. 3 
D. 4 

Question # 35

FusionModule1000A V2R3 version 40-foot IT scene can provide the number of cabinets (multiple choice) 

A. 5 
B. 6 
C. 7 
D. 8 
E. 9 

Question # 36

What are the fire-fighting linkage functions of FusionModule2000? ( ). 

A. Channel light on 
B. The access door is magnetically opened 
C. Air conditioner off 
D. Sunroof Flip 
E. UPS is powered off 

Question # 37

The difference between traditional power frequency machine and high frequency machine is: () (multiple choice)

 A. Different rectification methods
 B. The output must have a built-in step-up transformer 
C. Different types of bypass devices 
D. All of the above are true 

Question # 38

According to the ICT Research 2018 statistical report, the market share of Huawei's linelevel temperature control products in China in 2017 is: () 

A. First 
B. Second 
C. third 
D. Fourth 

Question # 39

Is the description of the iPower function of the intelligent micro-module of FusionModule2000 V3.0 correct? ( ) 

A. Power Distribution Link Visualization
 B. With alarm convergence function (mains power failure scenario, alarm information convergence). 
C. Intelligent rPDU can monitor the power consumption information of each outlet 
D. Can monitor battery information. 

Question # 40

When the power density of a single cabinet is greater than 10kl/R, which cooling form is recommended () 

A. Room-level air conditioning 
B. Row-level air-conditioning horizontal air supply airtight channel. 
C. Unsealed channel for horizontal air supply of row-level air conditioner 
D. Downstream air from room-level air conditioners 

Question # 41

The power supply architecture supported by the new room and air-cooled series is () 

A. Circuit Power 
B. Dual power supply 
C. AB are both right
 D. Other 

Question # 42

Huawei's main temperature control solution for small and medium-sized computer rooms is: 

A. Row-level chilled water with micro-modules 
B. Room-level air cooling solution 
C. Row-level air cooling with micro-modules 
D. Room-level chilled water solution 

Question # 43

Which core differentiated features of FusionModule800 can shield opponents? ( ). 

A. Rack-mounted inverter air conditioner 
B. Integrated design of cold and electric control. 
C. Light-load dehumidification of air conditioners 
D. ibattery. 

Question # 44

Regarding the intelligent battery management in UPS5000-A, the following statement is correct () 

A. Support battery temperature compensation 
B. Support battery sleep
C. The number of battery cells is adjustable 
D. Intelligent Floating Charge Conversion 

Question # 45

Configure the UPS system scheme, which of the following factors need to be considered in the calculation scheme ( ) 

A. UPS type, capacity and parallel mode 
B. The brand and capacity of the battery 
C. Make and model of AC and DC cables 
D. Configuration of battery rack and battery switch box 

Question # 46

Which of the following functions or components does the UPS5000-E (50kVA power module) come standard with? ( ) 

A. SNMP function
 B. Dry contact communication card 
C. Parallel function 
D. Bus synchronization control function 

Question # 47

Huawei Technologies Co., Ltd. is GB50174-2008 standard () is GB50174-2017 standard / 

A. Participating units, auditing units 
B. Participating units, participating units 
C. audit unit, audit unit 
D. Review unit, participating unit 

Question # 48

The dynamic environment monitoring system is usually used to monitor the following equipment? (Multiple choice)

 A. UPS 
B. Air conditioning 
C. Power distribution cabinet
 D. server 

Question # 49

The asset management module of the NetEco management system supports which of the following parameters can be used to quickly search for asset information? (Multiple choice) 

A. Name 
B. Location
 C. Type 
D. Status 

Question # 50

What type of equipment room is physically isolated in the power distribution room (multiple choice) 

A. Class A 
B. Class B 
C. Class C 
D. Tier IV 

Question # 51

Which modules can be hot-replaced online in UPS5000-E (50kVA power module)? ( ) 

A. Power Module 
B. Control Module 
C. Bypass Module 
D. Power distribution module: 

Question # 52

UPS5000-E-500K Regarding efficiency, which of the following options is correct? () 

A. Efficiency 96% 
B. Efficiency 94% 
C. ECO mode 99% 
D. ECO mode 98% 

Question # 53

Which of the following functions need corresponding hardware support? (). 

A. Power distribution links. 
B. Battery Management 
C. U bit self-identification 
D. Temperature cloud map 

Question # 54

What is the wrong description about the iManager function of FusionModule2000v3.0 version?

A. Support asset automatic configuration 
B. When the server is listed, the best server location can be recommended 
C. It can display capacity data such as space, power distribution, cooling, etc. 
D. All of the above 

Question # 55

Huawei's I Cooling. The energy-saving effect is () %. /

 A. 15% 
B. 10% 
C. 8% 
D. 5% 

Question # 56

Regarding fluorine pump type energy-saving air-conditioning products, which of the following statements is correct ((multiple choice) 

A. No or less compressors are turned on in autumn, winter and spring, indirect natural cooling and energy-saving operation, but it does not necessarily reduce OPEX. Because maintenance work and maintenance difficulty are simultaneously increasing 
B. The reliability of fluorine pump is relatively hidden, and it is easy to be damaged due to cavitation (gaseous refrigerant exists near the blades) 
C. There are no professional pump suppliers for fluorine pumps, and most of them are provided by pump manufacturers. The technology is immature and lacks professional technical support. 
D. At present, the main users are pilot computer rooms of operators and enterprise computer rooms with energy-saving innovation budgets. They have not been applied on a large scale, and are still pending on-site inspection. 
E. In most areas in China, because the temperature in winter is not low enough, the TCO advantage is not obvious. Generally, it takes 5~8 years to recover the investment, and the economy is poor 

Question # 57

When the distance between the outdoor unit and the seaside is 0.5km~3.7km, you need to configure the () outdoor unit 

A. Class d 
B. Class a
 C. class c 
D. class b 

Question # 58

Why are Fusionlodule500&FusionModule800 generally recommended to customers with typical configuration solutions? ( 

A. The existing typical configuration scheme can basically cover most of the small computer room usage scenarios 
B. Typical solutions are more competitive 
C. The typical configuration scheme has a shorter lead time than the customized scheme 
D. Typical configuration solutions are better than customized solutions 

Question # 59

Which of the following alarm functions does the PDU8000 precision power distribution cabinet branch circuit have: (multiple choice) 

A. Current high-threshold out-of-limit alarm 
B. Over voltage alarm 
C. High current impact alarm 
D. Over frequency alarm 
E. Branch overload 

Question # 60

Regarding the overload capacity of UPS5000-E, which of the following statements is correct ( ) 

A. Inverter 110% overload for 60 minutes 
B. Inverter 110% overload for 120 minutes 
C. Bypass 135% overload for 120 minutes
D. Bypass 135% overload long-term operation 

Question # 61

The NetEco6000 management system can provide monitoring of the cooling power system, and which of the following functions can be provided? ( 

A. The power distribution system topology diagram can be provided, and the power distribution system diagram of the entire computer room can be displayed 
B. Support the display of key equipment indicators on the power distribution topology diagram, which is convenient for users to understand the operation status of the system and important nodes 
C. It can provide the topological diagram of the chilled water system, showing the operation status of the whole system 
D. None of the above is supported 

Question # 62

In PDU8000, what are the optional functions ( 

A. Input switch remote tripping function 
B. Temperature Monitoring Feature Function 
C. Branch switch hot swap function 
D. 9 earthquake resistance 

Question # 63

Using UPS5000-E (50kVA power module), the actual load is 160kW, the rack 1+1 redundancy, the single-machine backup power scheme is adopted, each rack has 3 groups of batteries, each group is 30, and the capacity of the main switch box is ( ) 

A. 250A 
B. 320A 
C. 500A
D. 630A 

Question # 64

FusionMoudle2000 supports the following cladding scenarios () 

A. The column is located in the channel 
B. Column spanning aisle and column 
C. The column is located at the head or tail of the column 
D. Columns are located between columns 

Question # 65

What are the fire linkage functions of FusionModule2000? (multiple choice) 

A. Channel light on 
B. The access door is magnetically opened 
C. Air conditioner off 
D. Sunroof Flip 
E. UPS is powered off 

Question # 66

Which of the following functions or components does the UPS5000-E (50kVA power module) come standard with? ( ) 

A. SNMP function
B. Dry contact communication card 
C. Parallel function 
D. Bus synchronization control function 

Question # 67

A project requires the management system to be connected to two third-party generator sets (same model) 1 ATS (same model), six precision air conditioners (same model), and five smart meters (same model), then the management system Need to report () a third-party device access fee? () 

A. 3 
B. 10
 C. 14
 D. None of the above is true 

Question # 68

The root standard stipulates that the voltage drop of the AC cable should be controlled within 3%. It is recommended that the voltage drop of the AC cable should be controlled within ( ) when designing the UPS system. 

A. 0.02 
B. 0.05 
C. 0.03 
D. 0.01 

Question # 69

The NeEco6000 management system can provide monitoring of the cooling power system. Which of the following functions can it provide? (Multiple choices) 

A. The power distribution system topology diagram can be provided, and the power distribution system diagram of the entire computer room can be displayed
 B. Support the display of key equipment indicators on the power distribution topology diagram, which is convenient for users to understand the operation status of the system and important nodes
C. It can provide the topological diagram of the chilled water system, showing the operation status of the whole system 
D. None of the above is supported 

Question # 70

The number of battery strings that a single UPS5000 can support ( 

A. 4 groups 
B. Group 1 
C. Group 3 
D. 2 groups 

Question # 71

The standard communication methods of UPS5000-E are ( ) 

A. Dry contact 
B. RS485 
C. RS232 
D. SNMP 

Question # 72

The NetCol 8000-C room-level chilled water intelligent temperature control product has parts that can be plugged and maintained online, which can greatly reduce the time for parts replacement. ()

A. Main control module 
B. Auxiliary source module 
C. Electric heating 
D. Fan

Question # 73

What are the three-in-one access control methods of Fusionmodule2000 ( ) 

A. Password 
B. Fingerprints 
C. Swipe your card 

Question # 74

Huawei 25KW half-cabinet inverter air-cooled air conditioner, the following description is correct (multiple choice) 

A. The capacity algorithm for a single air conditioner with UPS is 1.2* 1.732*full load current*380*0.8/0.9 
B. The capacity algorithm for a single air conditioner with UPS is 1.2*5* 1.732*full load current*380*0.8/0.9 
C. The UPS capacity requirement of a single air conditioner is 15.8kVA. If you configure UPS5000E, you need to configure at least one 25kVA power module 
D. The UPS capacity requirement of a single air conditioner is 79.0kVA. If you configure UPS5000E, you need to configure at least two 40kVA power modules 
E. If a group of air conditioners is connected to a set of UPS systems, then it is necessary to multiply the number of air conditioners running at the same time on the basis of a single UPS, such as 5+1 cold backup configuration, then it needs to be based on the capacity requirement of a single air conditioner UPS Multiply by 5 to get total UPS capacity requirement, configure 

Question # 75

What is the correct function description of the intelligent micro-module iPower of Fusionllodule2000 v3.0 version? 

A. With alarm convergence function (mains power failure scenario, alarm information collection) 
B. Can monitor battery information 
C. Power Distribution Link Visualization 
D. The intelligent rPDU can monitor the electricity consumption information of each outlet 

Question # 76

In a single cabinet configuration scenario, which of the following scenarios can be configured? ( 

A. Fusionlodule2000 
B. FusionModule800 
C. FusionModule5000 
D. Fusionlodule500 

Question # 77

NETECO Which are the basic functions of the software and do not require separate and customer quotations ( ). 

A. GIS maps 
B. Battery Management 
C. Energy Efficiency Management 
D. Work Order Management 

Question # 78

Which of the following functions does the PDU8000 precision power distribution cabinet have? ( 

A. Main circuit and sub-circuit metering function of precision power distribution cabinet 
B. Power distribution function of data center micro-module (cabinet) 
C. The precision power distribution cabinet supports SNMP and MODBUS communication, which can transmit information to the intelligent monitoring system. 
D. Protection function of the lower line and equipment of the precision power distribution cabinet
 E. Abnormal alarm function of main circuit and sub-circuit of precision power distribution cabinet

Question # 79

Which of the following is true about the micro-module and fire protection system? () 

A. When a fire alarm occurs in the channel, the computer room controller (ECC800) can send the signal to the building fire protection system 
B. ECC800 can control sunroof rollover 
C. The building fire protection system can send fire signal to the computer room controller (ECC800) 
D. ECC800 controller can be linked with building fire 

Question # 80

What are the i3 features of FusionModule2000 V3.0 version? 

A. iCooling 
B. iPower
 C. iManager 

Question # 81

Which of the following voltage systems does the UPS5000-E support? 

A. 380V 
B. 480V
 C. 415V 
D. 400v

Question # 82

Among the following models, the one with the widest input frequency range is (). 

A. NXR 
B. UPS5000-A 
C. Galaxy5000 
D. 9390 

Question # 83

Which of the following communication functions does the UPS5000-E include? () (multiple choice) 

A. Dry contact card 
B. RS485 
C. SNMP 
D. RS232 

Question # 84

In UPS5000S, the adjustable range of the number of battery cells in a single group is 

A. Sections 30 to 44 
B. Sections 30 to 42 
C. Sections 30 to 46 
D. Sections 30 to 48 

Question # 85

The most energy-saving humidification method is () selection. 

A. Electrode humidification 
B. Infrared driving
C. Wet film humidification 

Question # 86

How many temperature and humidity monitoring modules are required for each temperature control product? 

A. 1 
B. 2
 C. 3 
D. 4 

Question # 87

UPS2000-G-(6K--20K) Regarding the optional output isolation transformer, the following statements are correct (). 

A. Can be connected to output isolation transformer 
B. Can be used as input isolation transformer 
C. It can convert one-way 220V into two-way 110V 
D. Can convert 50Hz to 60Hz Output 

Question # 88

The characteristics of UPS5000-A-400/500K in terms of ease of use, which of the following are correct 

A. Standard parallel board 
B. Covers an area of only 1.02 square meters 
C. The number of battery cells is adjustable 
D. Support intelligent battery management 

Question # 89

In the FusionModule2000 refrigeration system, the optional temperature control type () 

A. Half cabinet 25kW air cooling 
B. Half cabinet 30kW water cooling 
C. Row level chilled water 65kW 
D. Full cabinet 42kW air cooling 

Question # 90

NetCol5000-A025H Half-cabinet in-row air-cooled inverter precision air conditioner can match the outdoor unit model and adaptable temperature range: ().(Multiple choice) 

A. NetCol500-A026 (-20~45C ) 
B. NetCol500-A032 (-40~45C need to bring low temperature components) 
C. NetCol500-A036 (-20~55C ) 
D. NetCol500-A072 (-40~45C) 

Question # 91

Which of the following accessories in FM2000 can be adjusted in quantity ( ). / 

A. 1U dummy panel 
B. 2U dummy panel 
C. Rails
 D. side panel 
E. Beam Coil 

Question # 92

Which of the following accessories in FM2000 can be adjusted in quantity ( ). / 

A. 1U dummy panel 
B. 2U dummy panel 
C. Rails
 D. side panel 
E. Beam Coil 

Question # 93

Among the following options, which statement is correct about the reliability of UPS5000-A (30kVA~ 120kVA) ( ) 

A. 6kV/5kA lightning protection design 
B. Ultra-wide input voltage range 
C. Inverter overload capacity is strong 
D. Three anti-paint coating technology 

Question # 94

The fan control modes supported by the NetCo18000-C series room-level chilled water intelligent cooling products are ( ). 

A. Return air control 
B. Pressure Control 
C. Mixed air control
 D. Differential pressure control 
E. Supply air control 

Question # 95

UPS5000-series modular UPS product features are similar to which of the following product models? ( ) 

A. Hipulse-u 
B. 80-NET 
C. NXr 
D. APM 

Question # 96

Which of the following statements about micromodules is true? ( ) 

A. ECC800 can access no more than 4 external gates 
B. ECC800 can connect no more than 4 cameras 
C. ECC800 can be connected to iBattery battery management system 
D. ECC800 can provide SNMP northbound interface 

Question # 97

What are the fire-fighting linkage functions of FusionModule2000? 

A. Air conditioner off 
B. Sunroof Flip 
C. Channel light on 
D. Channel gate magnetic power down 

Question # 98

In the UPS5000 configurator, the optional module types are ( 

A. 50k efficient
B. 25k 
C. 50k standard effect 
D. 60k 

Question # 99

UPS5000-A has the industry-leading reliability design, then which of the following is correct about the reliability design of UPS5000-A? () (multiple choice) 

A. Strong grid adaptability, voltage input range of 138-485V 
B. The veneer is reinforced with conformal paint 
C. More than 1400 test guarantees 
D. 40 degrees without derating 

Question # 100

The NetEco6000 management system can provide the following access control card readers ( ). 

A. IC card reader 
B. Swipe PIN Reader 
C. Swipe fingerprint reader 

Question # 101

Which of the following modules does the UPS5000-E include that can support hot swapping? ( ) 

A. Control Module 
B. Power Module 
C. Bypass Module 

Question # 102

Compared with high-frequency machines, industrial frequency machines may bring more additional investment, including: () 

A. Refrigeration electricity bill 
B. Running electricity 
C. Room area 
D. Oil engine  
E. Mouth load-bearing (installation and construction) 

Question # 103

The UPS supports a variety of systems to meet customer application grid scenarios. Which systems does the UPS2000-G 15/20KVA model support? ( ) 

A. Single in, single out 
B. One in three out 
C. Three in and three out 
D. Three in and one out 

Question # 104

How many temperature and humidity monitoring modules can a single temperature control product be configured with? ( 

A. 6 
B. 4 
C. 2 
D. 8 

Question # 105

FusionModule1000A V2R3 version supports operation and maintenance methods (multiple choices) 

A. Local PAD operation and maintenance 
B. Remote mobile phone APP query, 
C. Remote WEB page query 
D. Remote mobile APP control 
E. Access to Huawei NetECO for centralized control 

Question # 106

What kinds of pillar-clad scenes are there in FM2000? (). 

A. Column in channel
 B. The column is in the cabinet. 
C. Columns span cabinets and aisles 
D. Columns at both ends of the cabinet 

Question # 107

The failure warning of key components in the UPS system can change the maintenance after the event into the maintenance before the event, so as to avoid the sudden power failure of the load. UPS2000-G devices that support early warning of failure include () 

A. Fan 
B. Bus Capacitance 
C. Output Capacitor 
D. Battery 

Question # 108

The asset management in the NetEco management system can manage the asset information of which of the following devices to realize the life cycle management of assets? (multiple choice) 

A. UPS 
B. Air conditioning 
C. Power distribution cabinet 
D. server

Question # 109

The characteristics of the compressor used by Huawei NetCo15000-A include: ( ). 

A. Highest volumetric efficiency, low noise and low vibration 
B. No reciprocating motion, less moving parts, high reliability+ 
C. International famous brand, long life, high reliability 
D. Safe operation under 3000V voltage. 

Question # 110

UPS5000-E can maintain high efficiency in a wide load range and effectively reduce losses. Among them, the efficiency can reach 96% at 40% load, and the efficiency can reach 95% at 20% load. What is the efficiency in ECO mode? ( ) 

A. 97%
 B. 99% 
C. 96% 
D. 98% 

Question # 111

Which of the following statements about micromodules is true? (multiple choice) 

A. ECC800 can access no more than 4 external gates 
B. ECC800 can connect no more than 4 cameras 
C. ECC800 can be customized to access third-party equipment
D. ECC800 can be connected to the CIM 
E. ECC800 can provide SNMP northbound interface for free 

Question # 112

FusionModule2000 product configuration framework, including which of the following (

 A. Cabinet System 
B. Power supply and distribution system 
C. Monitoring System 
D. Refrigeration system 

Question # 113

UPS5000-A about the characteristics of intelligence, which are correct? 

A. The NetEco monitoring software of UPS5000-A supports SMS or E-mail remote alarm 
B. Support NetEco monitoring software, support centralized monitoring of UPS 
C. Support battery intelligent management, effectively prolong battery life 

Question # 114

Considering that the UPS system is fully configured in the early stage of construction, but the actual system load rate is low, UPS5000-E is designed with an intelligent sleep function, which can increase the system load rate and keep the system running efficiently. When the UPS5000E sleeps intelligently, at least how many power modules are redundant?

A. 2 
B. 1 
C. 0 

Question # 115

If the customer has high requirements on the availability of the management system and requires that the normal use of the system is not affected by a single point of failure of the hardware, the NetEco management system can provide a high-availability solution of dual-system backup. What are the hardware resources required by NetEco in the dual-computer solution? ( 

A. 2 servers + 1 disk array + 1 switch 
B. 2 servers + 2 disk arrays + 3 switches 
C. 1 server + 1 t-disk array + 2 switches 
D. None of the above is true 

Question # 116

Regarding the Fusionlodule2000 wiring, which of the following statements is wrong? 

A. Cross-channel routing is through the control skylight 
B. The wiring trough supports the separation of strong and weak electricity 
C. The power distribution cabinet/integrated UPS can not be placed at the head of the column 
D. Cross-channel routing requires installation of cable ladders 

Question # 117

U-position self-identification technology is used to ensure accurate placement of IT equipment. Which feature of NetEco is this? 

A. Capacity Management 
B. Energy Efficiency Management 
C. Asset Management 

Question # 118

A UPS system is configured with a single 50mm "2 (209A) cable, and the maximum current capacity allowed by the system is . 

A. 174A 
B. 104A 
C. 209A 
D. 160A 

Question # 119

When the distance between the outdoor unit and the seaside is 0.5km~3.7km, you need to configure the () outdoor unit 

A. Class d 
B. Class a 
C. class c 
D. class b 

Question # 120

The circuit breaker of ( ) pole is generally used for the external maintenance bypass of the UPS system. 

A. 3 
B. 1 
C. 4 
D. 2 

Question # 121

FusionModule800UPS has a capacity ( ). 

A. 10kVA 
B. 15kVA 
C. 20kVA 
D. 30kVA 

Question # 122

FusionModule1000A V2R3 version 20 feet CT scene air conditioning features are (multiple choice) 

A. Air cooling 
B. Direct Expansion Refrigeration 
C. Water cooling 
D. Inverter compressor 
E. Free cooling technology 

Question # 123

A system is configured with a 5H battery backup time, and the discharge termination voltage of the battery cell should be selected from ()/ 

A. 1.75V 
B. 1.80V 
C. 1.60V 
D. 1.67V 

Question # 124

The environmental parameters of the data center host room are: ( ). 

A. Temperature 18~27C 
B. Dew point temperature 5.5~ 15C . 
C. The relative humidity is not more than 60%. 
D. No condensation in the computer room
E. Satisfy both ABCD. 

Question # 125

UPS2000-G-(6K-20K) Regarding the optional output isolation transformer, the following statements are correct () (multiple choice) 

A. Can be connected to output isolation transformer 
B. Can be used as input isolation transformer 
C. It can convert one channel of 220V into two channels of 110V 
D. Can convert 50Hz to 60Hz Output 

Question # 126

A project requires the management system to access a third-party generator set, two smart meters 1 (same model), and two precision air conditioners (same model), then the management system needs to report () a third-party equipment access fee ? ( 

A. 1 
B. 3 
C. 5 
D. None of the above is true 

Question # 127

NetEco6000 management system uses the above security mechanisms to ensure network security and prevent the leakage of business sensitive data? (multiple choice) 

A. Permission Control 
B. Transmission Security 
C. Storage Security
 D. None of the above is true 

Question # 128

Which of the following UPS does not have a neutral line (). 

A. UPS5000-H 
B. UPS5000-E 
C. galaxy5000 
D. APM150 

Question # 129

Using UPS5000-E (50kVA power module), the actual load is 160kW, the rack 1+1 redundancy, the single-machine backup power scheme is adopted, the backup power scheme for each machine, each rack has 3 sets of batteries, each set of 40 cells, The main switch box capacity is ( 

A. 630A 
B. 500A 
C. 250A 
D. 320A 

Question # 130

Which of the following tasks does the work of data center operation and maintenance include? (multiple choice)

A. Real-time monitoring 
B. Routine Maintenance 
C. Major overhaul 
D. Emergency drills 

Question # 131

If a project needs the management system to monitor the PUE value of the room, what function does NetEco need to quote separately? 

A. No separate quotation is required 
B. Capacity Management 
C. Mobile APP 
D. Energy Efficiency Management 

What our clients say about H19-371_V1.0 Exam Simulations

Leave a comment

Your email address will not be published. Required fields are marked *

Rating / Feedback About This Exam