• support@dumpspool.com

SPECIAL LIMITED TIME DISCOUNT OFFER. USE DISCOUNT CODE TO GET 20% OFF DP2021

PDF Only

Dumpspool PDF book

$45.00 Free Updates Upto 90 Days

  • OSP-002 Dumps PDF
  • 169 Questions
  • Updated On October 04, 2024

PDF + Test Engine

Dumpspool PDF and Test Engine book

$65.00 Free Updates Upto 90 Days

  • OSP-002 Question Answers
  • 169 Questions
  • Updated On October 04, 2024

Test Engine

Dumpspool Test Engine book

$55.00 Free Updates Upto 90 Days

  • OSP-002 Practice Questions
  • 169 Questions
  • Updated On October 04, 2024
Check Our Free BICSI OSP-002 Online Test Engine Demo.

How to pass BICSI OSP-002 exam with the help of dumps?

DumpsPool provides you the finest quality resources you’ve been looking for to no avail. So, it's due time you stop stressing and get ready for the exam. Our Online Test Engine provides you with the guidance you need to pass the certification exam. We guarantee top-grade results because we know we’ve covered each topic in a precise and understandable manner. Our expert team prepared the latest BICSI OSP-002 Dumps to satisfy your need for training. Plus, they are in two different formats: Dumps PDF and Online Test Engine.

How Do I Know BICSI OSP-002 Dumps are Worth it?

Did we mention our latest OSP-002 Dumps PDF is also available as Online Test Engine? And that’s just the point where things start to take root. Of all the amazing features you are offered here at DumpsPool, the money-back guarantee has to be the best one. Now that you know you don’t have to worry about the payments. Let us explore all other reasons you would want to buy from us. Other than affordable Real Exam Dumps, you are offered three-month free updates.

You can easily scroll through our large catalog of certification exams. And, pick any exam to start your training. That’s right, DumpsPool isn’t limited to just BICSI Exams. We trust our customers need the support of an authentic and reliable resource. So, we made sure there is never any outdated content in our study resources. Our expert team makes sure everything is up to the mark by keeping an eye on every single update. Our main concern and focus are that you understand the real exam format. So, you can pass the exam in an easier way!

IT Students Are Using our BICSI Outside Plant Designer (OSP) Dumps Worldwide!

It is a well-established fact that certification exams can’t be conquered without some help from experts. The point of using BICSI Outside Plant Designer (OSP) Practice Question Answers is exactly that. You are constantly surrounded by IT experts who’ve been through you are about to and know better. The 24/7 customer service of DumpsPool ensures you are in touch with these experts whenever needed. Our 100% success rate and validity around the world, make us the most trusted resource candidates use. The updated Dumps PDF helps you pass the exam on the first attempt. And, with the money-back guarantee, you feel safe buying from us. You can claim your return on not passing the exam.

How to Get OSP-002 Real Exam Dumps?

Getting access to the real exam dumps is as easy as pressing a button, literally! There are various resources available online, but the majority of them sell scams or copied content. So, if you are going to attempt the OSP-002 exam, you need to be sure you are buying the right kind of Dumps. All the Dumps PDF available on DumpsPool are as unique and the latest as they can be. Plus, our Practice Question Answers are tested and approved by professionals. Making it the top authentic resource available on the internet. Our expert has made sure the Online Test Engine is free from outdated & fake content, repeated questions, and false plus indefinite information, etc. We make every penny count, and you leave our platform fully satisfied!

Frequently Asked Questions

BICSI OSP-002 Sample Question Answers

Question # 1

OTDRs are used in outside plant cables to \_\_\_\_\_\_\_\_\_\_.

A. Verify splice loss
B. Measure length
C. Find faults
D. All of the above

Question # 2

What is the cable from the telecom closet (room) to the work area called?

A. Horizontal cabling
B. Backbone cabling
C. Work area cable
D. Patchcord

Question # 3

The diameter of an optical fiber is traditionally measured in \_\_\_\_\_\_\_\_\_\_.

A. Meters
B. Millimeters
C. Microns (micrometers)
D. Nanometers

Question # 4

How many methods are included in standards for setting the ”0 dB‘ reference for loss testing?

A. One
B. Two
C. Three
D. Four

Question # 5

The wavelength of light used for most fiber optic systems is in the __________ region and __________ to the human eye.

A. ultraviolet, invisible
B. solar, visible
C. infrared, invisible

Question # 6

What is the MINIMUM lighting requirement for telecommunications spaces?

A. 50 lux (4.6 foot-candles) of lighting in the horizontal plane and 20 lux (1.9 foot-candles) of lighting in the vertical plane measured at 1 meter (3.28 feet) above the finished floor
B. 200 lux (18.6 foot-candles) of lighting in the horizontal plane and 500 lux (46 footcandles) of lighting in the vertical plane measured at 1 meter (3.28 feet) above the finished floor
C. 500 lux (46 foot-candles) of lighting in the horizontal plane and 200 lux (18.6 footcandles) of lighting in the vertical plane measured at 1 meter (3.28 feet) above the finished floor
D. 500 lux (46 foot-candles) of lighting in the horizontal plane and 500 lux (46 foot-candles) of lighting in the vertical plane measured at 1 meter (3.28 feet) above the finished floor

Question # 7

Which punchdown block is more often used with POTS telephone connections?

A. Bix block
B. Krone block
C. 110 block
D. 66 block

Question # 8

What copper cable types are included in the TIA-568 structured cabling standards?

A. UTP (unshielded twisted pair), STP (shielded twisted pair) and coax
B. UTP (unshielded twisted pair) and coax
C. UTP (unshielded twisted pair), ScTP (screened twisted pair) and STP (shielded twisted pair)
D. Any communications cable

Question # 9

Wireless networks require cables to connect the server, router or hub to the \_\_\_\_\_\_.

A. PC
B. Uplink
C. SNMP
D. AP (Access point)

Question # 10

Most \_\_\_\_\_\_\_\_\_ are designed to allow easy pulling.

A. Cables
B. Cable trays
C. Cable boxes
D. Ropes

Question # 11

Loss of a fiber or any fiber in a cable is measured in __________.

A. dB
B. dBm
C. milliwatts

Question # 12

You can keep track of how much cable is left in a box if you ___________.

A. Record on the cable box the beginning distance marked on the cable
B. Read the distance off the cable
C. Weigh the box
D. You can’t

Question # 13

Does a jack have the same color code for the pairs as a punchdown block?

A. No
B. Yes
C. Depends on the type and manufacturer of the jack
D. Depends on whether it is T568A, T568B or USOC

Question # 14

Which type of dispersion affects singlemode fiber as well as multimode fiber?

A. Modal
B. Differential
C. Chromatic
D. Polarization mode

Question # 15

Multiple Response: Identify one or more choices that best complete the statement or answer the question. Which of the following communications systems typically use fiber optic backbones? (choose all that apply)

A. Telephones
B. CATV
C. Internet
D. Cell Phones

Question # 16

Structured cabling standards call for a maximum length of multimode fiber optic cable for backbones of \_\_\_\_\_\_\_\_\_\_.

A. 800 meters
B. 1000 meters
C. 3000 meters
D. 2000 meters

Question # 17

FDDI and Token Ring networks used a \_\_\_\_\_\_\_\_\_\_\_ architecture.

A. Bus
B. Star
C. Ring
D. Balanced

Question # 18

Hardware like video cameras designed to run on coax can be used on UTP with a converter device called a \_\_\_\_\_\_\_\_\_.

A. Splitter
B. Balun
C. Adapter
D. TOSLINK

Question # 19

___________ should be used to bundle cables since _________.

A. Hook and loop cable ties, tight cable ties can affect cable performance
B. Cable ties tightened with guns, cables should not be allowed to move around
C. Cable ties, loose cables are a safety hazard
D. Rubber bands, they stretch

Question # 20

What kinds of connection to the cable does a UTP jack typically have?

A. 66 punchdown
B. 110 punchdown
C. Snap-in contacts
D. Solder connections

Question # 21

What kinds of connection to the cable does a UTP jack typically have?

A. 66 punchdown
B. 110 punchdown
C. Snap-in contacts
D. Solder connections

Question # 22

What kinds of connection to the cable does a UTP jack typically have?

A. 66 punchdown
B. 110 punchdown
C. Snap-in contacts
D. Solder connections

Question # 23

Multiple Response: Identify one or more choices that best complete the statement or answer the question.Preparing cables for splicing in splice closures requires __________.

A. Leaving the proper length of buffer tubes from the cable entrance in the closure to the splice tray
B. Leaving the proper length of fiber to splice and fit the splice in the splice tray
C. Securing the cable properly at the closure entrance
D. Careful cleaning of all fibers

Question # 24

\_\_\_\_\_\_\_\_\_\_ is the standard which forms the basis of structured cabling in the US?

A. IEEE 802.3
B. EIA/TIA 568
C. EIA/TIA TR42
D. NEMA 63.1999

Question # 25

___________ should be used to bundle cables since _________.

A. Hook and loop cable ties, tight cable ties can affect cable performance
B. Cable ties tightened with guns, cables should not be allowed to move around
C. Cable ties, loose cables are a safety hazard
D. Rubber bands, they stretch

Question # 26

What is the installed cable plant from work area outlet jack to the patch panel in the elecom closet called?

A. Permanent link
B. Channel
C. Link cable
D. Patchcord

Question # 27

Which network connection type has the highest bandwidth?

A. Power line
B. UTP
C. Wireless
D. Optical fiber

Question # 28

The loss of a fiber optic connector is defined as _____?

A. The calculated loss due to geometric misalignment
B. The loss of the connector mated to another connector
C. One-half the loss of a mated pair of connectors
D. The loss of a statistical sample of connectors

Question # 29

Which punchdown block is more often used with data (Cat 5e/6)?

A. Bix block
B. Krone block
C. 110 block
D. 66 block

Question # 30

Rolling objects create what type of load on an access flooring system?

A. Dynamic
B. Impact
C. Static
D. Physical
E. Virtual

Question # 31

The international standard for structured cabling is \_\_\_\_\_\_\_\_?

A. TIA-568
B. ISO-11801
C. ISO-9000
D. IEC-0001

Question # 32

The Cat 3 jack is the same as a Cat 5e/6 jack except _________.

A. There are no internal twists to enhance performance
B. The punchdowns fit bigger wires
C. It only connects to RJ-45 plugs
D. It is keyed to snap into outlets upside down

Question # 33

The \_\_\_\_\_\_\_\_\_\_ protects the fiber from harm.

A. Primary buffer coating
B. Aramid fiber strength members
C. Jacket
D. All of the above

Question # 34

An older fiber design with a 50/125 micron core is now being used in cabling systems because it___________.

A. Can be cabled in more compact cable designs
B. Costs half as much as other multimode fibers
C. Has a higher bandwidth with laser sources which gives more distance capability with gigabit (and above) networks
D. Excess supplies are currently available from the far east

What our clients say about OSP-002 Practice Test

flags     Elliot Sanders     Oct 07, 2024
Dumpspool provided me Well-organized and structured content for BICSI Outside Plant Designer (OSP) exam.
flags     Gavin Green     Oct 06, 2024
OSP-002 practice tests Boosted my confidence to tackle the actual exam.

Leave a comment

Your email address will not be published. Required fields are marked *

Rating / Feedback About This Exam